Helion power modules
Common questions about charging and storage power modules.
Mainly input voltage and ambient temperature. Below the rated input range or above the rated temperature, the module derates automatically to protect itself.
On power-up the module ramps its output gradually instead of jumping to full load, which avoids inrush stress on the grid and the vehicle.
Standard Helion modules communicate at 125 kbps by default; 250 kbps and 500 kbps can be set through configuration.
It shuts down safely when input leaves the allowed window and restarts on its own once voltage returns to normal.
CCS1, CCS2, CHAdeMO and NACS, depending on model and region. Liquid-cooled cables are available on high-power models.
Yes. OCPP 1.6J is standard and OCPP 2.0.1 is available on current firmware.
We recommend a visual inspection every six months and filter cleaning once a year for air-cooled units.
Yes. Helion Cube and Boost systems can form their own microgrid with solar or a generator.
Firmware security notices are posted on this page and emailed to registered partners. Report issues via the contact page.
Can't find your question? Get in touch at support@helion-ev.example